DENTAL EQUIPMENT --->

RXDC Intraoral DC X-Ray

     

Myray

 

The RXDC's small focal spot (0.4mm) and 12" rectangular collimator guarantees consistently-sharp images while minimizing radiation exposure to the patient. Easy-to-use and handle, the wireless remote offers a full-range of intuitive exposure scenarios designed to make the X-ray acquisition process straightforward and accurate. The full-swivel ball joint is revolutionary in every sense: the tube head revolves freely around the sphere so that virtually any desired position can be achieved. An automatic tough sensitive locking and unlocking mechanism allows for effortless, positioning.
Total freedom
RXDC features HyperSphere technology. The full-swivel ball-joint is revolutionary in every sense. The tube head revolves freely around the sphere, so that practically any position can be achieved, including complete vertical. An automatic touch-sensitive lock-on/lock-off device enables effortless repositioning of the tube head between exposures.
Comfortable grip
Ergonomically shaped areas on either side of the tube head make rapid positioning easy and effortless to achieve. Right at your finger tips
Lightweight and Compact
RXDC is equipped with an 8” X-ray collimator entirely integrated into the tube head body.
This makes the tube head itself a more compact lightweight component than would otherwise be possible. The unique tube head design, together with the stable aluminium arms, make this unit effortless to manoeuvre. RXDC is supplied with a standard rectangular cone which extends just 4” beyond the tube head body, resulting in a 12” long rectangular collimation. The operator is free to remove and replace the rectangular cone extension. This triggers an automatic preset of exposure times which are displayed on the handheld control device. There is no need to re-program before acquisition.

RXDC Technical Specifications

Classification Electro-medical equipment Class I type B
Generator: Constant potential controlled via microprocessor
operating frequency 120 KHz - 215 KHz (150 KHz typical)
Tube Toshiba D-041DC
Focal spot 0.4 mm, square, IEC 336
Irradiated field 35 x 45 mm, rectangular or Ø 60 mm round
Total filtration 2.5 mm Al
Anode current 7 mA – 3 mA
Voltage (kV setting) 60 kVp
Exposure Time 0.010 – 1.000 sec., R10 and R20 scale
Source-skin distance 30 cm rectangular or 20 cm round
Line voltage 50/60 Hz, 115V or 230V ± 15%
Duty cycle self regulating, continuous operation up to 1s/60s
Stability Automatic touch-sensitive lock-on/lock-off (HyperSphere)
Arms Available in 3 lengths: 40 cm – 60 cm – 90 cm
Max arm extension 230 cm, from wall
Certification CE 0051
Item# Description Price
70640000 RXDC HyperSphere Unit 115 V $4,995.00
70670000 RXDC eXTend Unit 115 V - Economy  no-locking system $4,595.00

 

You are visitor no.
Dental Equipment Site Counter
 

Copyright © 2000-2010 KAB Dental. All Rights Reserved. (Kabdental.com)