ASDEX AS-9 Amalgam Separator
(ISO 11143
Certified ISO Rated 99.0%)

(2000D & MBK-1)
Single
Chairside System Portable System/Mobile System
|
Item # |
Description |
Price |
|
AS10S |
Complete System
Includes: 1
Manifold Head Assembly, 1-Mount Bracket,
1-Replacement Separator
(as-10) 14" long |
$233.00 |
|
2000D |
Manifold Head
Assembly |
$104.00 |
|
MBK-1 |
Mounting Bracket |
$30.00 |
|
AS-10 |
Replacement
Separator 14" long |
$90.00 |
Mounting Space
Required: 5"x14"
Average Life: 4-8 Months
Flow Rate: 1L/MN ISO Rated: 99.0%
Replacement Schedule: When vacuum is depleted to
mouthpiece or 1 year.
Dispose in accordance with any and all local,
State & Government guidelines. |
Central Vacuum System 2-4 Chairs
|
Item # |
Description |
Price |
|
AS20S |
Complete
System
Includes: 1-Manifold Head Assembly,
1-Mounting Bracket, 1-Replacement Separator
(as-20) 24" long |
$332.00 |
|
2000D |
Manifold Head
Assembly |
$104.00 |
|
MBK-1 |
Mounting
Bracket |
$30.00 |
|
AS-20 |
Replacement
Separator 24" long |
$198.00 |
Mounting Space
required 5"x 24"
Average Life: 4-8 Months
Flow Rate: 1L/MN ISO Rated: 99.0%
Replacement Schedule: When vacuum is
depleted to mouthpiece or 1 year.
Dispose in accordance with any and all
local, State & Government guidelines. |
For Portable & Mobile Systems
|
Item # |
Description |
Price |
|
AS5S |
Complete
System
Includes: 1 Manifold Assembly, 1-Mount
Bracket, 1-Replacement Separator (AS-5) 7"
Long |
$204.00 |
|
200D |
Manifold Head
Assembly |
$104.00 |
|
MBK-1 |
Mounting
Bracket |
$130.00 |
|
AS-5 |
Replacement
Separator 7" long |
$75.00 |
|
Installation Instructions
for AS-9 Amalgam Separator
Central
Vacuum System: 2-4 chairs
-
Install the
ASDEX Manifold Head Assembly (2000D) in a
location as close to vacuum pump as
practical.
-
The system
needs to be mounted in a vertical position.
-
Do not remove
ty-wrap from manifold until manifold
installation is complete.
-
Use mounting
bracket (MBK-1) to mount manifold.
-
Out port
(note arrow) goes to vacuum pump, in port
(note arrow) goes to vacuum line leading to
dental operatory.
-
Remove and
save the two disposal caps from the ASDEX
Separator.
-
Before
installing ASDEX AS-20 Amalgam Separator
remove ty-wrap from manifold head assembly.
Chair Side:
Single Chair
-
Install the ASDEX Manifold Assembly near
chair.
-
The system
needs to be mounted in a vertical position.
-
Do not remove
ty-wrap from manifold until manifold
installation is complete.
-
Use mounting
bracket (MBK-1) to mount manifold.
-
Out port
(note arrow) goes to vacuum pump, in port
(note arrow) goes to mouthpiece.
-
Remove and
save the two disposal caps from the ASDEX
Separator.
-
Before
installing ASDEX AS-20 Amalgam Separator
remove ty-wrap from manifold head assembly
|
How do I
know when to replace the separator
For 2-4 operatory dental practice the
original separator may require replacement
in about 1.5 years. When the separator is
90% full, your vacuum in the mouthpiece will
be low and continue to go lower.
You will need to do the following:
- Order #AS-20 replacement separator:
call 800-422-3520
- Contact "Maguire & Strickland" to
order prepaid waste recycling & disposal
service. Call 800-486-2858. They are
based in Minneapolis, MN. Their charge
as of January 6th 2009 is $89.95 KAB
Dental is not associated with any
recyclers.
Click Here for Information of other Approved Amalgam Recyclers.
|
|